Hydronic Heat Updates for 2009-11-24

Posted By: SteveH  //  Category: hydronic heat
  • Time to buckle down to design and quote several hydronic heat systems – I need to finish 6 bids today… #
  • One radiant heating system quote down, 5 more to go today… #
  • ♫ – Another radiant quote bites the dust… #
  • hydronic heat for a 3-car shop, less than $3.50/square foot, just in time for lunch ☺ #
  • It’s getting cold, if U need a quote for #radiantheat just @ me w/info for radiant heat designs, PEX tubing, custom manifolds/controls… #
  • Just whipped out an example of counter-flow hydronic heat design…it confused the customer, but it’s the best thing for his shop #
  • Just quoted a high-efficiency, fully zone-able hydronic heating/cooling package at less than $8.50/SF #
  • If you want to design your own hydronic heat system, please start w/ a heat load calculation – or risk painting yourself into a corner #
  • For 1/2″ PEX tubing – loop lengths of 300′ to 350′ are recommended #

Powered by Twitter Tools

Technorati Tags: hydronic floor heat, hydronic heat, hydronic heating

Hydronic Heat Updates for 2009-11-17

Posted By: SteveH  //  Category: hydronic heat
  • I’m using Google Wave to collaborate with a hydronic heat design/DIY customer…would anyone else like to try? #
  • I just had to tell a guy his single loop of 1/2″ PEX – 964 feet long wouldn’t heat his shop properly – lack of hydronic heat design – #fail #

Powered by Twitter Tools

Technorati Tags: hydronic floor heat, hydronic heat, hydronic heating

Hydronic Heat Updates for 2009-11-10

Posted By: SteveH  //  Category: hydronic heat
  • Looking for people who 1)would like a hydronic heat design/system & 2)would like to use @GoogleWave – 7 invites left (RT) #
  • I’m having a blonde moment (actually about an hour now) – forgetting to set the right account in seesmic for @ replies…sorry ;-) #
  • With multiple Twitter accts & Seesmic – Enable “smart account selection” – it should choose the right acct for replies. (RT) #
  • Back to designing hydronic heating systems… #

Powered by Twitter Tools

Technorati Tags: hydronic floor heat, hydronic heat, hydronic heating

Hydronic Heat Updates for 2009-11-10

Posted By: SteveH  //  Category: hydronic heat
  • Looking for people who 1)would like a hydronic heat design/system & 2)would like to use @GoogleWave – 7 invites left (RT) #
  • I’m having a blonde moment (actually about an hour now) – forgetting to set the right account in seesmic for @ replies…sorry ;-) #
  • With multiple Twitter accts & Seesmic – Enable “smart account selection” – it should choose the right acct for replies. (RT) #
  • Back to designing hydronic heating systems… #

Powered by Twitter Tools

Technorati Tags: hydronic floor heat, hydronic heat, hydronic heating